Chromatography columns separate molecules within mixtures during gas or liquid chromatography. Filled with stationary phase compositions or chemical compounds, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual solvent polarity, composition, and size. The right chromatography control system allows to automate the delivery of cleaning, sanitizing and conditioning buffers to the packed column, and can enable to cycle the chromatography column several times during the batch, requiring smaller columns and subsequent lower capital investment.

Chromatography columns separate molecules within mixtures during gas or liquid chromatography. Filled with stationary phase compositions or chemical compounds, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual solvent polarity, composition, and size. The right chromatography control system allows to automate the delivery of cleaning, sanitizing and conditioning buffers to the packed column, and can enable to cycle the chromatography column several times during the batch, requiring smaller columns and subsequent lower capital investment.


18  个查询结果

SearchResultCount:"18"

Sort Results

查看清单 Easy View (new)

评价这些搜索结果

供应商: HAMILTON BONADUZ
描述: RCX-30 carbohydrate analysis columns are designed for the isocratic or gradient separation of carbohydrates. When an isocratic method is used with a conductivity, refractive index, ultraviolet, or pulsed amperometric detector (PAD), mono and disaccharides such as glucose, fructose, sucrose and lactose can be quickly determined.

供应商: HAMILTON BONADUZ
描述: Silica-based 100 Å columns for general reversed phase separations.

供应商: HAMILTON BONADUZ
描述: HC-75 columns separate compounds through ligand exchange. The different forms of the HC-75 (hydrogen, calcium and lead) each provide a unique selectivity for separating varying types of charged analytes based on electronegativity toward the counterion.

供应商: HAMILTON BONADUZ
描述: Polymeric cation exchange columns for the isocratic separation of mono and divalent cations.

供应商: HAMILTON BONADUZ
描述: PRP-X110 columns are designed for use in systems employing suppressed/non-suppressed conductivity, electrochemical, UV, and ICP-MS detection.

供应商: HAMILTON BONADUZ
描述: RCX-10 carbohydrate analysis columns are designed for the isocratic or gradient separation of carbohydrates. When an isocratic method is used with a conductivity, refractive index, ultraviolet, or pulsed amperometric detector (PAD), mono- and di-saccharides such as glucose, fructose, sucrose and lactose can be quickly determined.

供应商: HAMILTON BONADUZ
描述: PRP-C18 polymeric HPLC columns are designed to provide high efficiency, reversed phase separations over an extended column life in nearly any mobile phase or pH.

供应商: HAMILTON BONADUZ
描述: The PRP-X100 is a polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm. These columns can be used to separate ions at concentrations from 1 to 1000 ppm without suppression or elaborate preconcentration techniques. The highly inert polymeric support resists chemical attack from organic solvents and aqueous buffers (0 - 100% aqueous or organic; pH 1 to 13), effectively lengthening column life.

供应商: HAMILTON BONADUZ
描述: Polymeric cation exchange packing for separation of glyphosate and its metabolite in drinking water.

供应商: HAMILTON BONADUZ
描述: This anion column line is designed to meet the special requirements of anion analysis. These four columns cover all aspects of standard anion analysis, separation of all 8 common anions in one run. The unique design of the highly cross-linked porous-packing material, and the strong covalent bonded surface chemistry, ensure excellent durability and high separation efficiency. These columns are designed to be used with carbonate-bicarbonate buffer in any concentration or with hydroxide gradient, and many other mobile phases.

供应商: HAMILTON BONADUZ
描述: A fast, versatile HPLC column packing material. These columns rapidly and easily separate closely related alcohols and organic acids without column heating. The sulfonated poly(styrene-divinylbenzene) support separates samples by a mixed mode mechanism. A wide range of samples can be analysed with these columns because the selectivity of the column can be altered by changing the pH of the buffer or adding an organic modifier (methanol, acetonitrile) to the buffer. The stability to organic solvents makes it possible to analyse samples that have been too highly retained on conventional ion exclusion supports.

供应商: HAMILTON BONADUZ
描述: PRP-h5 polimeric reversed phase columns are ideal for applications that require a high degree of column-to-column and batch to batch consistency (quality assurance, clinical trials). Unlike C8 or C18 columns, PRP-h5 has no stationary phase coating. The integral reversed phase characteristics of the PRP-h5 column eliminate the need for special coating techniques. Since there is no stationary phase to hydrolyse, the column maintains its performance characteristics longer than many C8 or C18 columns. PRP-h5 columns are packed with a poly(styrene-divinylbenzene) material.

供应商: HAMILTON BONADUZ
描述: PRP-1 polymeric HPLC columns are designed for broad ranging uses, similar to C8 or C18 HPLC materials. They combine the best characteristics of silica-based and polymeric columns resulting in highly inert and long-lasting columns. These columns are ideal for applications that require a high degree of column to column and batch to batch consistency (quality assurance, clinical trials). Unlike C8 or C18 columns, PRP-1 has no stationary phase coating. Since there is no stationary phase to hydrolyse, the column maintains its performance characteristics longer than many C8 or C18 columns.

供应商: HAMILTON BONADUZ
描述: PRP-X600 is a superficially porous weak-base anion exchange support that separates DNA oligomers according to negative charge.

供应商: HAMILTON BONADUZ
描述: PRP-3 polymeric reversed phase columns are ideal for gradient separations of peptides and proteins. The columns are packed with a poly(styrene-divinyl)benzene support.

供应商: HAMILTON BONADUZ
描述: Polymeric cation exchange packing for separation of inorganic and organic cations.

询价
这一项的产品库存是有限的,但是可能在靠近你在一个仓库中提供.请确保您已登录到该站点,这样可以显示库存.如果call显示仍然有库存,且您需要帮助,请致电400-821-8006.
这一项的产品库存是有限的,但是可能在靠近你在一个仓库中提供.请确保您已登录到该站点,这样可以显示库存.如果call显示仍然有库存,且您需要帮助,请致电400-821-8006 .
此产品订购可能会受到监管部门审核,而产生额外的费用或者需要额外的文件。如需相关资料,我们通常会在3日内联系您。如有任何问题,请联系我们的客户服务部门: CS_CN@avantorsciences.com
此产品订购可能会受到监管部门审核,而产生额外的费用或者需要额外的文件。如需相关资料,我们通常会在3日内联系您。如有任何问题,请联系我们的客户服务部门: CS_CN@avantorsciences.com
您所在的组织机构无法订购此产品,请联系您的采购部门以获取更多信息。
原有的产品已不再提供,所示的替换产品
此产品已停产,您可以通过搜索上面的VWR目录号来选择替代产品。如需更多帮助,请致电VWR客户服务部400-821-8006。
1 - 16 of 18
no targeter for Bottom